  • A6VE

  • XLF

  • 00001

|

 Product technical data

XLF-A6VE Axial Piston Fixed Pump Features

- Fixed pump with axial tapered piston rotary group ofbent-axis design, for hydrostatic drives in an open circuit

- For use in mobile and stationary applications- The flow is proportional to the drive speed and displacement

- The drive  shaft bearings are designed for the bearing servicelife requirements usually encountered in these areas

- High power density

- Small dimensions

- High total efficiency

- Economical design

- One-piece tapered piston with piston rings for sealing



|

 XLF-A6VE Axial Piston Fixed Pump Product detail picture

A6VE (1)


A6VE (2)

A6VE (3)


|

 Application Video


|

 XLF-A6VE Axial Piston Fixed Pump Technical data

RE  91606/10.07   |A6VE                                                                   Bosch   AG         5(16
Technical Data
Shaft seal ring
Temperature range
Permissible  pressure  load The FKM shaft seal ring is permissible for case temperatures of
-25°℃ to +115°C.
The service lifte of the shaft seal ring is affected by the speed
of the motor and the case drain pressure.It is recommended
that the average,continuous case drein pressure at operating
temperature 3 bar absolute not be exceeded (max.permissible
case drain pressure 6 bar absolute at reduced apeed,see dia-
gram).Short  term(t<0.1  s)pressures  spikes  of  up  to  10  bar
absalute are permitted.The service life of the shaft seal ring de-
creases with an increase in the frequency of pressures spikes.
The case pressure must be equal to or greater than the extemal
pressure on the shaft seal ring.
Note:
For application  cases  below-25°C,an  NBR shaft seal  ring  is
necessary  (permissible  temperature  range:-40°℃ to  +90°C).
Please state NBR shaft seal ring in plain text when ordering.
Please  cantact  us.
Effect of case pressure on start of control
An increase in the case pressure has an effect on the following
controls when control of the variable motor begins:
      HA1T(sizes  28  to  160)
__ increase
HD,ER,HA,HA.T(size 250)
increase

__
DA_          _
decrease
The start of control is set in the factory at a case pressure of
Pata=2  bar  (sizes  28  to  160)and  Pa=1  bar  (eize  250).
Speed n in   pm 一
Table    of    values  (theoretical  values,without  eficiency  and  tolerances;values  rounded)
Size                                                        Size 28      55      80      107     160     250
Displacement 1)                                            cm⊃3; 28.1    54.8   80      107     160     250
Vao            cm⊃3; 0       0      0       0       0       0
Speed max.                           mu at y               rpm 5550   4450    390     3550    310    270
(while adhering to                   NmtatV.cV              rpm 8750    7000    615     5600    4900    3600
max.permissible flow)                Van=0.63xV            cm⊃3; 18      35      51      68      101     1882
Nmwa at V              rpm 10450   8350    7350    6300    550     3600
Max flow                             9vm                    Umi 156     244    312     380     496     675
Max torgue                            Tma,at Va   3         Nm 179     349     509     681     1019    1391
Rotary stifiness  Vema to Vgz        Cmn                    Nm/rad 5670    10400   15500   21000  35300   59500
Vaa to Oinarpdaed  Cmax                  Nm/rad 18100   32000   47900   65200   105000  181000
Moment of inertia for rotary group   Jw                    kgm⊃2; 0.0014 0.0042  0.008   0.0127 0.0253  0.061
Angular acceleration maximum         a                     md/e3 47000   31500   24000   19000   11000   10000
Filling capacity                     V                     L 0.5     0.75    1.2     1.5     2.4     3.0
Mass(apprax.)     Port plate 02      m                     kg 16      26      34      47      64      90
Port plate 22      m                     kg 35      43      53      72      一
1)The minimum and maximum displacements are infinitely variable,see ordering codes on page 2.
(default  settings  for  sizes  250  unless  specified  in  order:Vemn=0.2·Vama  Vamar  =Vg.
2)Vg₁=0.75xVgma(approx.)
3)Sizes   28   to   160:Ap=400   bar;size   250:Ap=350   bar
Caution:     Exceeding the permissible limit values may result in a loss of function,a reduction in service lfe or in the
                 destruction of the axial piston unit.

Other permissible limit values with respect to speed variation,reduced angular acceleration as a function of the fre-
      quency and the permissible startup angular acceleration (lower than the maximum angular acceleration)can be found
      in data sheet RE 90261.
For further information see technical data sheet RE 91604(variable motor A6VM):
-Selection diagrarm and details regarding the choice of hydraulic fluid
-Parmissible displacement and inlet pressure in relation to apeed
-Permissible radial and axial loading on drive shaft
-Description  and  dimensions  of the  control  units


Previous: 
Next: 

Related Products

Contact Us
Copyright © 2023 Wuhan xinlaifu hydraulic equipment Co. LTD  |  Sitemap | Privacy Policy | Support By leadong

Quick Links

All Products

Contact Us

Address: Shenghua Industrial Park, Xincheng 12 road, Dongxihu District, Wuhan, China
Phone: +86-18908655554
WhatsApp: +86-18908655554
Email: service@xlf-hydraulic.com